How to Read and Understand a VURB Performance Report

SUBSCRIBE FOR UPDATES

VURB performance report showing building energy analysis results

Introduction – Why VURB Performance Reports Matter

For architects, building designers, builders, volume builders, planners, surveyors, and property consultants, the VURB Performance Report is one of the most technically demanding compliance documents in residential building approval in Australia. Yet many professionals receive a VURB Performance Report and are unsure how to verify its accuracy, interpret its outputs, or confirm whether it genuinely demonstrates NCC performance solution compliance. VURB — Verification Using a Reference Building — is a performance solution Verification Method under the National Construction Code (NCC) 2022, maintained by the Australian Building Codes Board (ABCB). A VURB Performance Report documents the results of performance modelling that compares a proposed building’s thermal energy loads against a hypothetical reference building that fully complies with the Deemed-to-Satisfy (DtS) provisions. Understanding how to read this Performance Report is critical to ensuring building approvals proceed without delay. This guide provides a step-by-step walkthrough of every section of a VURB Performance Report — technically verified against NCC 2022 Volume Two Part H6 and the ABCB Performance Solution Process Handbook.

What Is a VURB Performance Report?

A VURB Performance Report is the formal technical document produced by an accredited energy assessor or performance modelling specialist that records the entire VURB compliance process and outcome. As a recognised ncc performance solution under Verification Method H6V2 (NCC Volume Two, Class 1 buildings) or J1V5 (NCC Volume One, Class 2 SOUs and Class 4 parts of buildings), the VURB Performance Report constitutes the legal evidence of compliance that building certifiers and building surveyors rely upon to grant a Construction Certificate or Building Permit.

A valid Performance Report under VURB must demonstrate that the proposed building’s annual heating and cooling loads — determined through performance modelling using ANSI/ASHRAE Standard 140 validated software — are equal to or less than those of the reference building. As confirmed by the ABCB, NatHERS-accredited software (FirstRate5, Hero, AccuRate, BERS Pro) is explicitly NOT permitted for VURB performance modelling. The Performance Report must reference validated simulation software — typically commercial tools such as DesignBuilder (powered by EnergyPlus) — to satisfy the NCC’s modelling requirements.

Understanding the VURB Assessment Process

Before reading a VURB Performance Report, it is essential to understand the performance modelling process it documents. According to the ABCB’s Verification Using a Reference Building resource, the VURB assessment involves six structured steps:

  • Step 1 — Software selection: The assessor selects energy simulation software validated to ANSI/ASHRAE Standard 140. NatHERS software is not permitted.
  • Step 2 — Reference building modelling: The reference building is modelled with mandatory DtS parameters from Table V2.6.2.2 of NCC Volume Two — identical geometry and orientation to the proposed building, but with NCC minimum insulation, standard glazing, and prescribed occupancy schedules.
  • Step 3 — Reference building loads calculated: Annual heating and cooling loads (in MJ/m²/year) are calculated for the reference building model through performance modelling. These loads define the maximum allowable threshold for the proposed building.
  • Step 4 — Proposed building modelled: The actual proposed building design is modelled — including actual insulation R-values, window glazing specifications (U-values and SHGC values per orientation), shading devices, orientation, and construction type.
  • Step 5 — Proposed building loads calculated: Annual heating and cooling loads are calculated for the proposed building through the same performance modelling
  • Step 6 — Comparison and compliance determination: If the proposed building’s heating and cooling loads are equal to or less than the reference building loads, the design is compliant. The VURB Performance Report documents this comparison and declares the compliance outcome.

Key Sections of a VURB Performance Report

There is no prescribed format for a VURB Performance Report under the NCC — however, as confirmed by the ABCB Performance Solution Process Handbook, the report must clearly demonstrate that compliance with the relevant NCC Performance Requirements has been achieved, with all methodology, assumptions, and results documented. The following table maps the essential sections that every valid VURB Performance Report must contain:

Section

Purpose

What to Check

1. Project Details

Identifies the building, assessor, NCC version, climate zone

Confirm project address, NCC 2022, correct climate zone (NCC 1–8)

2. Compliance Pathway Declaration

States VURB as the performance solution under H6V2 or J1V5

Confirm reference to H6V2 (Vol. 2) or J1V5 (Vol. 1)

3. Software Declaration

Names the ANSI/ASHRAE Standard 140 validated software used

Must NOT be NatHERS software; confirm e.g. DesignBuilder/EnergyPlus

4. Reference Building Model

Defines the DtS-compliant hypothetical reference building

Parameters from Table V2.6.2.2 (NCC Vol. 2) or Spec 34/44 (Vol. 1)

5. Proposed Building Model

Actual proposed building design with all specifications

Check insulation R-values, glazing U-values/SHGC, orientation, shading

6. Performance Modelling Output

Annual heating and cooling loads for both buildings (MJ/m²)

Proposed loads must be ≤ reference loads to demonstrate compliance

7. Compliance Conclusion

States whether proposed building meets or fails the target

Look for explicit compliance declaration with supporting load figures

8. Specification 44 Inputs

Energy value calculations (Class 2 SOUs / Class 4 parts)

Only required for Volume One pathway; verify if applicable

9. Design Recommendations

Design changes needed if not yet compliant

Check against current architectural plans before lodging DA/CC

How Performance Modelling Works in VURB

Hourly Simulation Methodology

Performance modelling in a VURB Performance Report uses hour-by-hour energy simulation — typically 8,760 hourly data points across a full year — using climate data specific to the building’s NCC climate zone. Unlike the prescriptive NatHERS pathway, which uses the CSIRO Chenath simulation engine with standardised occupancy assumptions, VURB performance modelling uses the ASHRAE 140 validated engine to model more detailed hourly thermal dynamics. This includes the thermal interaction between envelope components, solar radiation, internal heat gains, and ventilation — giving a more holistic picture of actual building energy performance.

As confirmed by the NCC 2022 Housing Energy Efficiency Webinar, the VURB performance modelling for NCC 2022 must incorporate specific operating schedules for heating and cooling, thermostat settings, and maximum occupancy assumptions — all prescribed under NCC H6V2(3). These are the same conditions applied to both the reference building and proposed building models in the Performance Report, ensuring a technically valid apples-to-apples comparison.

What the Performance Modelling Output Shows

When reviewing the performance modelling output section of a VURB Performance Report, look for three key load figures expressed in MJ/m² per year:

  • Annual heating load: Energy required per square metre of floor area to maintain comfortable temperatures in winter. Must be ≤ reference building heating load.
  • Annual cooling load: Energy required per square metre of floor area to maintain comfortable temperatures in summer. Must be ≤ reference building cooling load.
  • Total thermal energy load: Combined annual heating plus cooling load per square metre. Under NCC 2022, H6V2 also assesses total thermal energy load. All three — heating, cooling, and total — must individually meet or beat the reference building targets to confirm ncc performance solution

Understanding NCC Performance Solutions

VURB is a Verification Method — a specific, pre-defined type of ncc performance solution — under the performance-based structure of the NCC. As the ABCB Performance Solution Process Handbook explains, a performance solution provides an alternative to the prescriptive Deemed-to-Satisfy (DtS) pathway and must demonstrate that the NCC Performance Requirements — in this case H6P1 for thermal performance — are met. The key distinction: a Verification Method such as VURB is an agreed assessment method that, if correctly applied, is accepted as evidence of compliance without requiring the additional expert opinion evidence that other Performance Solution types demand.

The Performance Report for a VURB performance solution must comply with the documentation requirements of NCC clause A2G2(4)(d), as outlined in the ABCB Performance Solution Process Guidance Document. This includes: the performance requirement being addressed (H6P1); the Verification Method used (H6V2 or J1V5); the methodology and software; all assumptions and modelling parameters; results; and the compliance conclusion. A VURB Performance Report that omits any of these elements is technically deficient and should not be accepted by a building certifier as valid ncc performance solution evidence.

Step-by-Step Guide to Reading a VURB Performance Report

Step 1 — Verify the Project Identification

Confirm the project address, building class, NCC edition (must be NCC 2022 for current projects), and NCC climate zone (1–8). An incorrect climate zone in a Performance Report fundamentally compromises the entire VURB compliance result — reference building loads are climate-zone-specific. Verify against the ABCB NCC climate zone definitions.

Step 2 — Confirm the Performance Solution Pathway

The Performance Report must explicitly state that VURB under H6V2 (NCC Volume Two) or J1V5 (NCC Volume One) is the compliance pathway. Check that the applicable NCC Volume is correctly identified — Volume Two for Class 1 houses; Volume One for Class 2 SOUs and Class 4 parts.

Step 3 — Check the Software Declaration

The Performance Report must name the ANSI/ASHRAE Standard 140 validated software used. If the report references NatHERS-accredited software (FirstRate5, Hero, AccuRate, BERS Pro), the VURB performance modelling is technically invalid under the NCC and should not be accepted.

Step 4 — Scrutinise the Reference Building Definition

The reference building in the Performance Report must be modelled with the mandatory parameters from Table V2.6.2.2 of NCC Volume Two (or Specification 34 for Volume One). Any deviation from these prescribed parameters — particularly regarding thermostat setpoints, occupancy schedules, infiltration rates, or internal heat gains — will produce a skewed reference load that makes the performance solution non-compliant.

Step 5 — Review the Proposed Building Specification

Cross-check every proposed building specification in the Performance Report against the architectural drawings: insulation R-values for ceiling, walls, and floor; window glazing U-values and SHGC values by orientation; shading device details; orientation; and construction type. Any discrepancy means the Performance Report does not represent the building that will be constructed — rendering its performance modelling compliance conclusion invalid.

Step 6 — Read the Compliance Load Comparison Table

The core of every VURB Performance Report is a compliance table showing reference building loads versus proposed building loads in MJ/m²/year for heating, cooling, and total thermal energy. For compliance, all three proposed loads must be equal to or less than the corresponding reference loads. If even one load exceeds its reference target, the performance solution has not been demonstrated.

Common Mistakes When Interpreting Performance Reports

As an accredited energy assessor, the following mistakes are consistently observed when architects, builders, and building certifiers review VURB Performance Reports:

Common Mistake

Why It Matters

How to Avoid

Wrong NCC climate zone

Changes all load targets — wrong compliance result

Verify against NCC climate zone map at ncc.abcb.gov.au

NatHERS software used for VURB

Technically invalid — not permitted under NCC

Confirm ASHRAE 140 validated software is declared in the report

Reference building incorrectly defined

Inflated or deflated benchmark distorts compliance

Check Table V2.6.2.2 / Spec 44 parameters are applied exactly

Design drawings don’t match report

Compliance conclusion invalid if specs changed

Cross-check window schedules, insulation specs, and shading

Loads compared in wrong units

MJ/m² vs MJ total — significant error risk

Ensure loads are expressed per floor area (MJ/m²/year)

Performance modelling uses incorrect occupancy

Changes thermostat/schedule assumptions

Confirm operating schedules comply with NCC 2022 H6V2(3) criteria

Critical Rule: A VURB Performance Report that passes on total thermal energy load but fails on either the individual heating or cooling load is not compliant. All three load thresholds — heating, cooling, and total — must each individually be met. This is a common error in performance modelling interpretation that causes building certification rejections.

Benefits of VURB Performance Reports in Energy Compliance

A VURB Performance Report — when correctly prepared and verified — delivers significant advantages over the prescriptive NatHERS star rating pathway for eligible residential projects:

  • Design flexibility: The holistic performance modelling approach allows trade-offs across the building envelope — high-performance insulation compensating for lower-specification glazing, or superior north-facing solar access offsetting below-par eastern glazing. The Performance Report captures this net performance picture in a way prescriptive NatHERS cannot.
  • Cost-effective glazing compliance: As confirmed by the ABCB, VURB performance modelling frequently enables lower-cost glazing products to achieve compliance, saving significant construction costs on high-glazing-ratio designs.
  • Applicable to Class 1a and Class 1b buildings: Unlike standard NatHERS assessments (Class 1a only), VURB covers both Class 1a detached and Class 1b buildings — a key advantage for boarding houses, certain holiday homes, and other Class 1b residential uses.
  • Optimised shading modelling: The performance modelling engine in a VURB Performance Report can accurately model complex external shading devices — louvres, fins, screen panels — with hour-by-hour solar radiation calculations, delivering compliance outcomes that simplified NatHERS shading modelling cannot.
  • Future electrification readiness data: The hourly performance modelling outputs in a VURB Performance Report can also inform equipment sizing for heat pump systems and evaluate on-site renewable energy feasibility — value beyond the immediate compliance objective.

 

Conclusion

A VURB Performance Report is technically sophisticated, and correctly interpreting it requires understanding the VURB performance modelling process, the NCC’s performance solution framework, and the specific compliance criteria under NCC 2022 H6V2 and J1V5. For architects, building designers, builders, planners, surveyors, and property consultants, the ability to read and verify a VURB Performance Report — checking the climate zone, software declaration, reference building parameters, proposed building specifications, and compliance load comparison table — is an essential professional competency. An accurate, complete Performance Report produced through rigorous performance modelling is one of the most powerful compliance tools available for complex residential projects. For authoritative guidance on VURB, ncc performance solution requirements, and residential energy efficiency, visit the Australian Building Codes Board and the National Construction Code.

FAQs

1. What is a VURB performance report?

A VURB Performance Report is the formal technical document that records the Verification Using a Reference Building (VURB) performance modelling process and its compliance outcome under the NCC 2022. It is a recognised ncc performance solution under Verification Method H6V2 (NCC Volume Two, Class 1 buildings) or J1V5 (NCC Volume One, Class 2 SOUs). The report must be prepared using ANSI/ASHRAE Standard 140 validated software — NatHERS-accredited software is explicitly not permitted. The Performance Report demonstrates that the proposed building’s annual heating and cooling loads are equal to or less than a DtS-compliant reference building, confirming energy efficiency compliance under NCC 2022

2. Why is a performance report important for compliance?

A VURB Performance Report is the legal evidence of compliance that building certifiers and building surveyors require before issuing a Construction Certificate or Building Permit for projects using the VURB ncc performance solution pathway. Without a valid Performance Report that correctly documents the performance modelling process, reference building definition, proposed building specifications, and load comparison results, a building certifier cannot accept VURB as the compliance method. An inaccurate or incomplete Performance Report causes building approval delays and may require costly redesign or reassessment

3. What is performance modelling in VURB assessments?

Performance modelling in VURB assessments uses energy simulation software validated to ANSI/ASHRAE Standard 140 to calculate the annual heating and cooling loads (in MJ/m²/year) for both the reference building and the proposed building. Unlike the prescriptive NatHERS star rating method, VURB performance modelling uses hour-by-hour (8,760 hourly data points) simulation to model the full thermal dynamics of both buildings — including solar radiation, internal heat gains, occupancy schedules, and ventilation — as prescribed under NCC 2022 H6V2(3). The performance modelling output is the core of the VURB Performance Report’s compliance determination.

4. When is a VURB performance report required?

A VURB Performance Report is required when a residential building project is using VURB as the ncc performance solution compliance pathway for thermal performance under NCC 2022 H6P1 (Performance Requirement for thermal performance). This is typically because the building cannot meet the standard NatHERS 7-star requirement due to high glazing ratios, poor orientation, steel-frame thermal bridging, or constrained site conditions. The Performance Report must be prepared before a Construction Certificate or Building Permit is issued and submitted with the required development approval documentation

5. Who prepares a VURB performance report?

A VURB Performance Report is prepared by an accredited energy assessor or specialist performance modelling consultant with experience in ANSI/ASHRAE Standard 140 validated simulation software. Because NatHERS-accredited software cannot be used for VURB, a standard NatHERS assessor without training in commercial simulation tools such as DesignBuilder or EnergyPlus cannot prepare a valid VURB Performance Report. Engage a specialist with demonstrated VURB assessment experience, verified against the ABCB’s performance solution guidance and the NCC 2022 H6V2 / J1V5 Verification Method requirements.