VURB Assessment NCC 2022: What Information Your Energy Assessor Needs, Why NatHERS Software Cannot Be Used, and How Verification Using a Reference Building Saves Design Cost

SUBSCRIBE FOR UPDATES

VURB assessment process diagram | NCC 2022 VURB assessment compliance pathway | energy assessment reference building comparison

Introduction - VURB Assessment NCC 2022: What Information Your Energy Assessor Needs, Why NatHERS Software Cannot Be Used, and How Verification Using a Reference Building Saves Design Cost

If you are an architect, building designer, builder, or homeowner working on a new residential project in Australia, understanding the VURB assessment under the National Construction Code 2022 (NCC 2022) is essential. A VURB assessment — Verification Using a Reference Building — is a Performance Solution pathway under NCC 2022 that enables compliance with energy efficiency requirements by comparing a proposed building’s thermal performance against a code-compliant reference building, rather than achieving a standard 7-star NatHERS rating. This alternative energy assessment method is particularly valuable for complex, non-standard, or architecturally ambitious designs that cannot easily meet Deemed-to-Satisfy (DtS) provisions. This blog explains exactly what information your energy assessor requires, why NatHERS software is explicitly prohibited from VURB, and how this NCC performance solution can save significant design cost.

What Is a VURB Assessment Under NCC 2022?

A VURB assessment is a formal Verification Method under NCC 2022 Volume Two, Clause H6V2 (for Class 1 and Class 10 buildings) and NCC 2022 Volume One, Verification Method J1V5 (for Class 2 apartments and Class 4 parts of buildings). It is defined and administered by the Australian Building Codes Board (ABCB). Instead of relying solely on a star rating produced by NatHERS-accredited software, a VURB energy assessment involves building two thermal simulation models: one for the proposed design and one for a hypothetical reference building that is fully compliant with DtS elemental provisions. If the proposed building’s annual heating and cooling loads are equal to or lower than those of the reference building, compliance is demonstrated under the NCC performance solution framework.

This approach, published and endorsed by the ABCB, was significantly updated in NCC 2022 to address misuse that had occurred under NCC 2019, where some VURB assessments were found to approve designs that did not genuinely meet the minimum energy efficiency intentions of the NCC. The revised VURB provisions now include tighter modelling requirements, including prescribed operating schedules, thermostat settings, and maximum occupancy parameters, providing greater rigour and consistency to the NatHERS assessment process.

What Information Does Your Energy Assessor Need for a VURB Assessment?

To conduct a thorough VURB energy assessment, your energy assessor must receive complete and accurate documentation of the proposed design. Incomplete information at the outset is one of the most common causes of delays and cost blowouts. The following information is required:

1. Architectural and Construction Documentation

  • Architectural drawings — floor plans, elevations, sections, and site plan
  • Roof framing and construction type (e.g., pitched tile, flat/low-slope metal deck)
  • Wall construction specifications (e.g., brick veneer, reverse brick veneer, lightweight clad frame)
  • Floor system details (slab-on-ground, suspended timber, or concrete)
  • Window and door schedules — sizes, orientations, frame types, and glazing specifications (U-value and Solar Heat Gain Coefficient / SHGC)
  • Insulation specifications — R-values for ceiling, wall, and underfloor where applicable
  • Shading devices — eaves depths, pergolas, external blinds, louvres (with dimensions)
  • Site orientation and climate zone confirmation

2. Services and Mechanical Information

  • Heating, ventilation, and air conditioning (HVAC) system type and efficiency ratings (COP/EER)
  • Hot water system type (electric resistance, gas continuous flow, heat pump, solar)
  • Lighting — type, power density, and control systems
  • Ceiling fan locations (required for Whole of Home modelling in Climate Zones 1 and 2)
  • Swimming pool or spa pump details (if applicable)
  • Any on-site renewable energy systems such as photovoltaic (PV) panels

3. Site-Specific and Regulatory Information

Your energy assessor also requires the confirmed climate zone (available via the ABCB climate zone maps), the building class, and the applicable NCC volume. For projects in NSW, the BASIX requirements also apply. The assessor will then construct the VURB reference building using the same geometry, orientation, and location as the proposed building, but with minimum DtS compliant specifications — replacing the actual glazing, insulation, and construction with code minimum values to create the benchmark.

Why NatHERS Software Cannot Be Used in a VURB Assessment

This is one of the most technically critical and commonly misunderstood aspects of the VURB assessment process. The ABCB has explicitly stated that NatHERS-accredited software tools — including AccuRate Sustainability, FirstRate5, HERO, and BERS Pro — cannot be used when developing a Performance Solution under H6V2. This requirement is codified in H6V2(1)(a) of NCC 2022 Volume Two, which states that the calculation method must be other than a software tool accredited or previously accredited under NatHERS, even when run in non-regulatory mode.

The Victorian Building Authority (VBA) guidance on NCC 2022 confirms: the VURB requires thermal software that complies with ANSI/ASHRAE Standard 140 — an internationally recognised standard for evaluating building energy analysis computer programs. NatHERS-accredited tools are not designed or validated to this standard.

Why This Distinction Matters

NatHERS-accredited software operates under a specific accreditation framework managed by the Nationwide House Energy Rating Scheme (NatHERS). These tools are calibrated and validated exclusively for the DtS NatHERS pathway. They use standardised occupant behaviour assumptions, fixed climate data files, and prescribed modelling rules. While excellent for producing star ratings, they do not offer the modelling flexibility, parametric analysis capability, or transparent load reporting required for a rigorous VURB energy assessment.

The VURB NCC performance solution instead relies on specialist building simulation tools such as IDA ICE, EnergyPlus, or DesignBuilder — software validated to ANSI/ASHRAE Standard 140. These platforms allow the energy assessor to model solar heat gain on an hourly basis, evaluate shading device performance accurately, perform design optimisation and trade-off analysis between insulation, glazing SHGC, and thermal mass. This level of physics-based modelling is what makes the VURB energy assessment genuinely flexible and cost-effective for complex projects.

How VURB Assessment Saves Design Cost

For architects, volume builders, and building designers, one of the most compelling reasons to consider a VURB assessment early in the design process is cost savings. The NatHERS assessment pathway, while straightforward, can force expensive specification upgrades — particularly for glazing. Under a standard 7-star NatHERS assessment, achieving compliance often demands double-glazed low-e windows with low SHGC values across large glazed facades, regardless of orientation and shading context. This can add tens of thousands of dollars to construction costs.

The VURB NCC performance solution allows your assessor to trade off between design elements holistically. For example, if a home has excellent northern passive solar design with well-proportioned eaves, the assessor can demonstrate through energy modelling that the overall heating and cooling loads remain below the reference building benchmark — even if individual glazing specifications do not strictly meet DtS requirements. This design-to-performance approach reflects how buildings actually work, capturing the interaction between orientation, thermal mass, ventilation, and shading rather than assessing each element in isolation.

Avoiding Late-Stage Design Rework

Another significant cost benefit of engaging a VURB energy assessment early is avoiding late-stage design rework. Under a standard NatHERS assessment, when a design fails to achieve 7 stars, the designer must change specifications and resubmit for re-rating. If the design is significantly non-compliant, multiple iterations may be required. Each iteration incurs both assessor fees and, more importantly, redesign costs and delays to the building approval process. When a VURB assessment is initiated during design development, the energy assessor can provide iterative modelling feedback as the design evolves, allowing the design team to make informed decisions in real time rather than discovering compliance issues at the documentation stage.

For volume builders and project home companies, the VURB approach can be particularly cost-effective when applied across a range of design variants. By modelling a suite of designs with different facades, orientations, and glazing options against the reference building, the volume builder can establish a compliance matrix that their sales and design teams can use directly — dramatically reducing the need for individual NatHERS assessments for every variant.

VURB Assessment vs NatHERS Assessment: Key Differences

Understanding the difference between a VURB assessment and a NatHERS assessment is critical for the right compliance strategy. Both are legitimate compliance pathways under NCC 2022, but they serve different purposes and involve different tools, outputs, and use cases.

Compliance Pathway: Proposed → Performance Solution (H6V2 / J1V5) | NatHERS → Deemed-to-Satisfy (Spec 42)

  • Governing Standard: Proposed → ANSI/ASHRAE Standard 140 | NatHERS → NatHERS Software Accreditation Protocol
  • Software Used: Proposed → IDA ICE, EnergyPlus, DesignBuilder (ASHRAE 140 validated) | NatHERS → AccuRate, FirstRate5, HERO, BERS Pro
  • Output: Proposed → Annual heating and cooling load comparison | NatHERS → Star rating (out of 10) + Whole of Home score
  • Covers Whole of Home?: Proposed → Thermal performance only (H6P1); H6P2 requires separate demonstration | NatHERS → Yes (when Whole of Home NatHERS tools used)
  • Best For: Proposed → Complex glazing, non-standard design, design optimisation, volume builder variants | NatHERS → Standard residential projects, straightforward designs
  • Design Flexibility: Proposed → High — trade-offs between all fabric elements allowed | NatHERS → Limited to DtS trade-off provisions.

When Should a VURB Assessment Be Commissioned?

The ideal time to commission a VURB assessment is during the design development phase, before construction documentation is finalised. For projects where the designer already suspects glazing ratios are high, orientation is suboptimal, or the DtS elemental provisions will impose restrictive specifications, early engagement with an energy assessor experienced in VURB modelling is essential. Surveyors and planners should also be aware that if a project involves an alteration or extension to an existing building where DtS compliance is not achievable, the VURB NCC performance solution is often the only viable energy compliance pathway.

Note that while the VURB addresses thermal performance (H6P1), it does not address the Whole of Home energy usage requirement (H6P2) for Class 1 buildings. Compliance with H6P2 must be demonstrated separately through either NatHERS Whole of Home tools or the ABCB Whole of Home calculator (subject to a maximum floor area of 500m²). For Class 2 buildings using J1V5, the VURB does cover both thermal performance and Whole of Home requirements under the Performance Solution framework.

Related Reading

For further guidance on energy compliance pathways in Australia, refer to our related articles on NatHERS assessment requirements, Section J compliance for commercial buildings, and passive design principles for Australian climates.

FAQs

1. What is a VURB assessment?

A VURB assessment — Verification Using a Reference Building — is a Performance Solution compliance pathway under NCC 2022 (H6V2 for Class 1 buildings; J1V5 for Class 2 buildings) that allows a proposed building design to demonstrate energy compliance by comparing its modelled annual heating and cooling loads to those of a code-compliant hypothetical reference building. If the proposed building performs equal to or better than the reference building, compliance is achieved without requiring a 7-star NatHERS rating.

2. What information is required for a VURB assessment?

Your energy assessor requires complete architectural drawings (floor plans, elevations, sections, site plan), full construction specifications (wall, roof, floor, and ceiling), a detailed window and door schedule including glazing U-value and SHGC, insulation R-values, shading device dimensions, HVAC system details, hot water system type, lighting specifications, on-site renewables if applicable, and climate zone confirmation. Incomplete information at project commencement is the primary cause of assessment delays.

3. How is VURB different from a NatHERS assessment?

A NatHERS assessment is a Deemed-to-Satisfy compliance pathway that uses NatHERS-accredited software (AccuRate, FirstRate5, HERO, BERS Pro) to generate a thermal star rating. A VURB assessment is a Performance Solution that uses ANSI/ASHRAE Standard 140-validated software such as EnergyPlus or IDA ICE to compare proposed vs. reference building loads. NatHERS produces a marketable star rating, while the VURB NCC performance solution provides maximum design flexibility. Importantly, NatHERS software cannot be used for a VURB assessment as explicitly stated in H6V2(1)(a) of NCC 2022.

4. What is an NCC performance solution?

An NCC performance solution is one of the three compliance pathways available under the NCC framework (alongside DtS solutions and Verification Methods). A Performance Solution allows a designer or assessor to demonstrate that a proposed building meets the intent of the NCC Performance Requirements (e.g., H6P1 Thermal Performance and H6P2 Energy Usage) using methods other than the prescriptive DtS provisions. The VURB is classified as a Verification Method, which is a specific type of Performance Solution with defined assessment criteria.

5. Can VURB help avoid design rework?

Yes — this is one of the primary benefits of early engagement with a VURB energy assessment. By running iterative energy modelling during design development, the assessor can identify compliance risks and inform design decisions before construction documentation is finalised. This eliminates the costly cycle of designing, rating, failing, redesigning, and re-rating that can occur with standard NatHERS assessment if the initial design does not achieve 7 stars.

6. What is energy modelling in VURB?

Energy modelling in a VURB assessment involves constructing detailed digital thermal simulation models of both the proposed and reference buildings using software validated to ANSI/ASHRAE Standard 140 (such as EnergyPlus, IDA ICE, or DesignBuilder). The software simulates hourly heat transfer across the building envelope over a full year, accounting for solar gain, thermal mass, conduction, ventilation, and internal gains. The resulting annual heating and cooling loads (in MJ/m²) are then compared between the two models to determine compliance.

7. When should a VURB assessment be done?

A VURB assessment should ideally be initiated during the design development phase — before construction documentation is finalised. For projects with complex glazing, high window-to-wall ratios, challenging orientations, or non-standard construction, early commissioning allows the energy assessor to provide compliance guidance that shapes the design rather than reacting to it. Building surveyors, planners, and property consultants should also be aware that for certain alterations and additions where DtS compliance is not achievable, the VURB NCC performance solution may be the only available pathway. For more on state-specific adoption timelines, refer to the NatHERS website and the ABCB website.