Introduction: What Is VURB and Why Does It Matter?
When navigating energy efficiency compliance under the National Construction Code (NCC) 2022, architects, builders, and designers face a critical decision: which compliance pathway best suits their project? VURB NCC 2022 — short for Verification Using a Reference Building — has emerged as a powerful alternative for projects where standard Deemed-to-Satisfy (DtS) provisions or NatHERS star ratings create design or cost challenges. VURB NCC 2022 sits within the performance solution framework of the NCC, offering a comparative modelling approach that measures a proposed building’s thermal performance against a code-compliant reference building. Under NCC 2022 Volume Two, the VURB compliance pathway is codified as H6V2 for Class 1 residential homes, while NCC 2022 Volume One, Section J, codifies it as J1V5 for Class 2 apartment sole-occupancy units (SOUs). Understanding the NatHERS VURB difference, the applicable building classes, and which software tools are required is essential for every project team aiming for compliant, innovative design.
What Is Verification Using a Reference Building?
At its core, the VURB method involves modelling two versions of the same building: the proposed design and a hypothetical reference building. The reference building is constructed using the minimum Deemed-to-Satisfy provisions — for Class 1, that means complying with the elemental fabric requirements of the ABCB Housing Provisions (Sections 13.2 to 13.5 for insulation, glazing, sealing, and shading). The proposed and reference buildings share identical geometry, orientation, location, internal heat gains, and infiltration rates. What differs is only their thermal fabric performance.
If the proposed building’s annual heating and cooling loads are equal to or lower than those of the reference building, compliance is achieved — even if the NatHERS star rating would otherwise be below 7 stars. This makes the VURB compliance pathway a design-friendly alternative for architecturally complex projects.
Crucially, the verification using reference building process requires thermal simulation software validated to ANSI/ASHRAE Standard 140 — the international standard for evaluating building energy analysis computer programs. This requirement is non-negotiable under both H6V2 NCC 2022 and J1V5 NCC 2022.
H6V2 NCC 2022 — VURB Compliance Pathway for Class 1 Residential Homes
Which Buildings Does H6V2 Apply To?
H6V2 NCC 2022 applies to whole Class 1a and Class 1b buildings — detached houses, terraces, townhouses, and small boarding houses — under NCC 2022 Volume Two, Part H6. VURB Class 1 homes compliance also extends to attached Class 10a components such as enclosed garages. It does not apply to detached garages or open carports.
What H6V2 Requires: Energy Budget Comparison
Under H6V2 NCC 2022, both the proposed building and the reference building are modelled to calculate annual heating load, cooling load, and total thermal energy load. Compliance is verified when the pro
posed building’s energy loads do not exceed those of the reference building, as specified under Specification 44 of NCC 2022.
Thermostat setpoints under H6V2 differ from NatHERS defaults — with heating set at 20°C and cooling at 25–28°C depending on climate zone. Internal heat gains are standardised at 5 W/m² averaged over 24 hours, and infiltration is set at 0.6 air changes per hour for both models.
Inputs and Variables: Fabric, Glazing, Orientation, and Ventilation
Both models share 17 locked parameters including orientation, floor plan, glazing locations, shading, and climate data. The only elements permitted to vary between models are thermal fabric characteristics: insulation R-values, glazing specifications (SHGC and U-value), roof colour, and thermal mass properties. This ensures a fair and direct comparison.
H6V2 vs NatHERS: Key Methodology Differences
The NatHERS VURB difference is significant. NatHERS assessments produce a star rating using software accredited by the Nationwide House Energy Rating Scheme (NatHERS), such as FirstRate5 or BERS Pro. These tools use specific modelling assumptions calibrated to the NatHERS framework, including different thermostat setpoints. The NatHERS VURB difference is that H6V2 NCC 2022 mandates ANSI/ASHRAE 140-compliant software — tools that operate on an hourly simulation engine capable of independently modelling the reference building without NatHERS-imposed constraints.
J1V5 NCC 2022 — VURB Compliance Pathway for Class 2 Apartments
Which Buildings Does J1V5 Apply To?
J1V5 NCC 2022 applies exclusively to Class 2 sole-occupancy units (SOUs) — individual apartments within multi-residential buildings. Introduced in NCC 2022 Volume One, Section J, J1V5 is an evolution of the former JV3 method, specifically adapted for the new VURB Class 2 apartments framework. It is not available in New South Wales, where BASIX governs residential energy compliance.
How J1V5 Integrates With Section J
J1V5 NCC 2022 addresses two performance requirements: J1P2 (thermal performance) and J1P3 (whole-of-home energy usage). Under J1V5(1), compliance with J1P2 is verified when the proposed building’s heating and cooling loads do not exceed those of the reference building across applicable climate zones. Under J1V5(2), J1P3 is satisfied when the energy value of the proposed building’s domestic services — including centralised hot water, heating, and cooling — is less than that of the reference building. Modelling profiles for J1V5 are provided in Specification 45 of NCC 2022 Volume One.
J1V5 vs H6V2: Practical Differences
While both H6V2 NCC 2022 and J1V5 NCC 2022 follow the VURB method, key differences exist. J1V5 NCC 2022 can model the energy performance of an entire apartment building — including common areas and centralised services — as a single model, making it particularly valuable for VURB Class 2 apartments with shared hot water systems or central HVAC. The reference building under J1V5 is specified with a 3-star ducted heat pump for heating and cooling and a 5-star instantaneous gas water heater.
When J1V5 Is Chosen Over the DtS Pathway
VURB Class 2 apartments using J1V5 NCC 2022 is typically chosen when: centralised services make individual NatHERS ratings impractical; the architectural form involves deep-plan layouts or minimal north-facing glazing; or the project uses innovative thermal envelope systems that exceed DtS assumptions but cannot be fully captured in a star rating.
Why NatHERS Software Cannot Be Used for VURB Assessments
This is one of the most critical points for project teams to understand. NatHERS VURB difference is not just a procedural issue — it is a fundamental incompatibility in modelling methodology.
NatHERS-accredited software such as FirstRate5, BERS Pro, and AccuRate Sustainability are designed to produce a house energy star rating. They operate using fixed NatHERS modelling assumptions — including specific thermostat setpoints, occupancy schedules, and infiltration rates — that differ from those mandated under H6V2 and J1V5. Furthermore, NatHERS software tools are not validated against ANSI/ASHRAE Standard 140, which is an explicit requirement of the NCC verification method.
What Software Tools Are Used for VURB?
The VURB method requires dedicated thermal simulation tools validated to ANSI/ASHRAE Standard 140. In practice, assessors across Australia use tools including:
- DesignBuilder / EnergyPlus — the most widely used platform for VURB NCC 2022 assessments
- IES Virtual Environment (IES-VE) — a powerful multi-zone simulation engine
- Speckel — an emerging cloud-based tool validated to ANSI/ASHRAE 140
- TRNSYS — commonly used for complex multi-zone commercial and residential modelling
These tools require specialist training and technical expertise beyond standard NatHERS accreditation. The NatHERS VURB difference in software therefore has direct implications for assessor selection and project timelines.
Where VURB Does Not Apply Under NCC 2022
The VURB compliance pathway is not universally available across all building classes or jurisdictions.
By building class: VURB does not apply to Class 3, Class 5–9 commercial buildings (which use JV3 or NABERS verification methods), or Class 10b structures. For Class 2 common areas, Section J’s DtS or JV3 pathways remain applicable.
By jurisdiction: H6V2 NCC 2022 and J1V5 NCC 2022 are not available in New South Wales (which uses BASIX), Tasmania (operating under NCC 2019 energy provisions for residential), or the Northern Territory (which has not adopted the updated NCC 2022 energy efficiency increases). The verification using reference building pathway is available in Victoria, Queensland, South Australia, Western Australia, and the Australian Capital Territory.
VURB in Practice: Process, Documentation, and Timelines
When to Engage a VURB Assessor
The VURB compliance pathway should be considered at design development stage — ideally before construction documentation is finalised. Early engagement allows the assessor to advise on fabric trade-offs (e.g., swapping roof insulation for higher-performance glazing) that may reduce construction cost while maintaining compliance. Engaging a VURB assessor after permit application can introduce costly design delays.
Documentation Requirements
A complete VURB NCC 2022 assessment submission typically includes: the thermal simulation model files (proposed and reference), a compliance report referencing the relevant NCC clause (H6V2 or J1V5), Specification 44 or 45 load limit calculations, and a statement confirming software compliance with ANSI/ASHRAE Standard 140. Documentation should align with the requirements of the relevant building surveyor or private certifier.
Common Modelling Errors to Avoid
Frequent errors in VURB NCC 2022 assessments include: using different infiltration rates between the proposed and reference models; applying incorrect thermostat setpoints; modelling skylights (which create asymmetries that are difficult to justify); and failing to lock all 17 required shared parameters. Assessors should ensure software output files are retained for audit purposes.
Conclusion: When VURB Is the Right Compliance Pathway
VURB NCC 2022 is the right choice when your building design cannot comfortably achieve a 7-star NatHERS rating through standard means, when centralised services make unit-by-unit NatHERS assessments impractical, or when architectural innovation requires a performance-based approach to demonstrate true energy equivalence. Whether via H6V2 NCC 2022 for Class 1 homes or J1V5 NCC 2022 for Class 2 apartments, the verification using reference building method provides a robust, code-recognised pathway to compliance.
At Torple (Axis Lifetech Pty Ltd), our ESD consultants are experienced in delivering VURB assessments using industry-leading thermal simulation platforms including DesignBuilder and IES-VE. We work with architects, builders, volume builders, and developers across Victoria, Queensland, South Australia, Western Australia, and the ACT to secure energy efficiency compliance without compromising design. Contact our team to discuss whether H6V2 or J1V5 is the right pathway for your next project.
FAQs
VURB — Verification Using a Reference Building — is a performance-based compliance pathway under the National Construction Code 2022. Under VURB NCC 2022, a proposed building is modelled against a hypothetical reference building that meets minimum DtS provisions. If the proposed building’s annual heating and cooling loads are equal to or lower than the reference building, energy efficiency compliance is achieved. It applies to Class 1 homes (H6V2, Volume Two) and Class 2 apartments (J1V5, Volume One).
H6V2 NCC 2022 is the Verification Method under Part H6 of NCC 2022 Volume Two that applies the VURB compliance pathway to Class 1 residential buildings — detached houses, townhouses, and terraces. It requires thermal simulation software validated to ANSI/ASHRAE Standard 140 and produces compliance by demonstrating that the proposed building’s heating and cooling loads do not exceed those of a DtS-compliant reference building, with load limits defined in Specification 44.
.
J1V5 NCC 2022 is a new Verification Method introduced under Section J of NCC 2022 Volume One, applying the VURB method to Class 2 sole-occupancy units (apartments). It verifies compliance with performance requirements J1P2 (thermal performance) and J1P3 (whole-of-home energy use) by comparing the proposed apartment building against a reference building. Modelling profiles are specified in Specification 45 of NCC 2022. It does not apply in NSW.
NatHERS VURB difference comes down to both methodology and validation. NatHERS-accredited software tools use different thermostat setpoints and modelling assumptions than those required under H6V2 NCC 2022 and J1V5 NCC 2022. Additionally, NatHERS tools are not validated against ANSI/ASHRAE Standard 140 — the international benchmark for building energy simulation software required by the NCC. Using NatHERS software for a VURB assessment would not produce a valid compliance outcome.
The NatHERS VURB difference is fundamental. NatHERS produces a star rating (out of 10) for a dwelling based on its thermal shell, using accredited software calibrated to NatHERS standards. VURB, by contrast, does not produce a star rating — it compares two energy models to determine if the proposed design performs at least as well as a code-minimum reference building. The NatHERS VURB difference also extends to software: VURB requires ANSI/ASHRAE 140-compliant tools, while NatHERS uses its own accredited software suite. The verification using reference building approach provides more design flexibility for complex or non-standard buildings.
Under VURB NCC 2022, the pathway applies to: Class 1a and Class 1b buildings (via H6V2, Volume Two) — detached houses, townhouses, terraces, and small boarding houses; and Class 2 sole-occupancy units (via J1V5, Volume One) — individual apartments in multi-residential buildings. VURB Class 1 homes and VURB Class 2 apartments pathways are available in Victoria, Queensland, South Australia, Western Australia, and the ACT. NSW, Tasmania, and the NT have different or deferred adoption arrangements.
The VURB compliance pathway is the right choice when: your Class 1 or Class 2 design cannot achieve the required NatHERS star rating using the DtS or standard software pathways; the building has complex geometry, dark facades, large glazing areas, or high thermal mass that creates asymmetries unfavourable to NatHERS; a Class 2 apartment building has centralised services that make unit-by-unit NatHERS ratings impractical; or design innovation requires a performance-based demonstration of energy equivalence. Engage a VURB-qualified ESD consultant early in design development to determine whether H6V2 NCC 2022 or J1V5 NCC 2022 is appropriate for your project.