Not every site plays nicely with a standard compliance checklist, and VURB exists for exactly the projects where it doesn’t — from single dwellings to larger commercial developments. When a sloping block, an unconventional building envelope, or a design constraint the standard software wasn’t built to handle keeps pushing a project toward a failed rating, this pathway offers a genuinely different way through — one based on whole-design energy modelling rather than forcing an unusual design into a standardised assessment it was never going to suit.
What Is This Assessment Method?
VURB stands for Verification Using a Reference Building — a Verification Method under NCC 2022 that assesses a residential design’s energy performance by comparing it against an equivalent benchmark, rather than relying on the standard NatHERS software route. Instead of a star rating, the design either meets or doesn’t meet the benchmark’s performance level, based on detailed energy modelling of both the proposed design and its reference equivalent.
When Should You Use This Pathway?
This pathway is worth considering whenever a design has features that make the standard software route difficult or unreliable — raked ceilings, extensive glazing, unusual orientation, or a building envelope that doesn’t fit the assumptions built into typical residential energy modelling tools used across most commercial developments. It’s also a strong option for challenging sites where the constraints are physical rather than architectural: steep slopes, tight boundaries, or overshadowing that limits solar access no matter how the floor plan is arranged.
Sloping and Constrained Sites
Sloping sites are one of the more common reasons a project turns to this pathway. Split-level designs, suspended floors, and awkward orientation options can all make it hard to achieve a passing outcome through standard means, even with a well-designed home. Because this pathway compares the proposed design’s actual energy modelling outcome against a fixed benchmark rather than checking elements individually, it can account for a sloping site’s genuine constraints in a way a prescriptive checklist can’t.
What Design Constraints Can This Pathway Address?
Beyond sloping sites, this pathway commonly helps with large expanses of glazing that a standard assessment would otherwise penalise, non-standard building envelope shapes like curved walls or unusual roof forms that standard energy modelling assumptions weren’t built to capture, heritage constraints that limit what can be changed to the existing fabric, and multi-dwelling projects — including commercial developments with a residential component — where a shared wall or unusual massing complicates a conventional assessment. In each case, the underlying idea is the same: use energy modelling to assess the whole design’s outcome against the reference building, rather than rejecting it for failing to match standard assumptions
Is This the Same as a Performance Solution?
Broadly, yes — this is one specific type of Performance Solution available for residential buildings, and both work on the same underlying principle of demonstrating an equivalent, or better, outcome rather than following prescriptive requirements element by element. The distinction is that this term refers specifically to the benchmark comparison method, while Performance Solution is the broader category that includes it alongside other verification approaches.
How the Reference Building Comparison Works
At the core of this pathway is a straightforward comparison: an assessor models the proposed design’s energy performance and compares it against a reference building built to standard requirements with the same floor area and classification. If the proposed design’s energy modelling shows it performs at or better than the reference building, it satisfies the requirement — even where individual elements, like a large area of west-facing glass, wouldn’t pass a standard checklist on their own.
Energy Modelling and the Building Envelope
Because the comparison is based on energy modelling rather than fixed element checks, the building envelope is assessed as a whole system rather than component by component, giving energy modelling the flexibility a prescriptive checklist doesn’t have. A weaker wall specification might be offset by better roof insulation, or a larger glazing area might be balanced by improved shading — the kind of building envelope trade-off that energy modelling can capture but a prescriptive, envelope-by-envelope checklist generally can’t.
Does This Pathway Replace a Section J Report?
No. Section J and its J1V3 Performance Solution pathway apply to commercial buildings (Class 3, and 5 to 9), while this method applies to residential buildings — Class 1 homes under H6V2, and Class 2 apartments under J1V5 (though J1V5 doesn’t apply in NSW). A mixed-use project with both residential and commercial components may need both a Section J report for the commercial areas and this pathway for the residential portion — they’re separate, parallel requirements rather than substitutes for each other.
Larger Residential and Commercial Developments
Townhouse and apartment projects — often run as commercial developments by builders and developers even though the buildings themselves are residential (Class 1 or Class 2) — benefit from this pathway for many of the same reasons a single dwelling does: shared walls, repeated unit types with variations, and site constraints across a whole site can make individual unit-by-unit assessment unreliable. It’s worth being clear on the distinction, though: for developments that also include genuinely commercial floor space — retail, office, or industrial components — those portions fall under Section J rather than this pathway, even within the same commercial developments overall.
Final Thoughts
Sites and designs that don’t suit a standard compliance checklist aren’t necessarily non-compliant — they often just need a method built around the whole design rather than its individual parts, whether that’s a single home or one of the larger commercial developments builders take on. This pathway gives challenging sites and unusual design constraints a genuine path to compliance through proper energy modelling, rather than forcing a design to compromise its intent to fit a prescriptive checklist. Torple’s VURB assessment service can determine whether this pathway suits a challenging site or design, and prepare the modelling required. For the official Verification Method provisions, see NCC 2022 on ncc.abcb.gov.au.
FAQs
It stands for Verification Using a Reference Building — a Verification Method under NCC 2022 that assesses a residential design’s energy performance by modelling it against that benchmark, rather than relying on the standard NatHERS software route.
When a design has features standard software struggles with — raked ceilings, extensive glazing, unusual orientation — or when a challenging site, like a steep slope or heavy overshadowing, makes standard compliance difficult to achieve.
Yes. Sloping sites are one of the most common reasons projects use this pathway, since split levels, suspended floors, and constrained orientation are easier to resolve through whole-design energy modelling than a prescriptive checklist.
Large glazing areas, unusual building envelope shapes, heritage constraints, and complex multi-dwelling massing are all common candidates, since each can be assessed holistically rather than element by element.
This is a specific type of Performance Solution for residential buildings, based on the reference building comparison method. Performance Solution is the broader category, which includes it alongside other verification approaches.
No. Section J applies to commercial buildings, while this pathway applies to residential buildings. A project with both components generally needs both, assessed separately.