1. Introduction: VURB Victoria Under NCC 2022 — What Changed and Why It Matters
Victoria’s residential building industry experienced a significant regulatory shift on 1 May 2024, when the updated energy efficiency provisions of the National Construction Code 2022 (NCC 2022) became mandatory for all new residential buildings across the state. At the centre of this transition is a compliance pathway that practitioners need to understand clearly: VURB Victoria — Verification Using a Reference Building — as prescribed under Verification Method H6V2 of NCC 2022 Volume Two. For architects, building designers, volume builders, and surveyors operating in Victoria, understanding how VURB Victoria functions is now essential to obtaining a valid building permit and avoiding non-compliance.
VURB Victoria provides an alternative performance-based compliance pathway for residential buildings that cannot or choose not to follow the standard NatHERS Deemed-to-Satisfy (DtS) route. Rather than achieving a prescriptive star rating, a VURB assessment benchmarks a proposed building design against a notional reference building modelled to minimum DtS standards, using advanced thermal simulation software validated against ANSI/ASHRAE Standard 140.
This article covers Victoria’s adoption of NCC 2022, how H6V2 operates as the operative verification method for VURB NCC 2022, what VBA Practice Note EE-03-2022 requires, the role of Specification 44, and practical compliance guidance for all Victorian practitioners and property professionals.
2. Victoria’s Adoption of NCC 2022
The 1 May 2024 Adoption Date and Its Implications
The Victorian Building Authority (VBA) confirmed that while NCC 2022 Victoria was initially adopted by all states and territories on 1 May 2023, Victoria extended the transitional period for energy efficiency, condensation management, and livable housing provisions. These updated requirements became mandatory on 1 May 2024, giving practitioners additional time to prepare. From this date, all building permits for new Class 1 and Class 2 residential buildings in Victoria must comply with the NCC 2022 energy efficiency framework, including VURB Victoria where applicable.
What Changed from NCC 2019 to NCC 2022 for Residential Buildings
NCC 2022 Victoria introduced several major changes for residential energy compliance compared to NCC 2019:
- 7-star NatHERS rating requirement (up from 6 stars) for most Victorian climate zones
- Whole-of-home energy budget assessment under Specification 42, covering all energy-consuming services
- Specification 44 — quantified heating, cooling, and total thermal energy load benchmarks replacing previous qualitative performance requirements
- VURB NCC 2022 formalised under H6V2 as the operative reference-building verification method for both Volume One and Volume Two residential buildings
- Condensation management requirements for all new residential buildings
Practitioners following NCC 2022 Victoria must note that energy compliance under NCC 2019 is no longer acceptable for new building permit applications lodged after 1 May 2024, except where transitional arrangements explicitly permit otherwise. Refer to Practice Note EE-05 — Transitional Energy Efficiency Arrangements for details.
3. How VURB Victoria Works Under NCC 2022
H6V2 as the Operative Verification Method
Under NCC 2022, H6V2 is the operative verification method for VURB Victoria in Volume Two (Class 1 and Class 10 buildings). H6V2 allows a practitioner to demonstrate compliance with the performance requirements H6P1 (thermal performance) and H6P2 (energy usage) by comparing a proposed building’s annual heating, cooling, and total thermal energy loads against those of a notional DtS-compliant reference building. Compliance is achieved when the proposed building’s loads do not exceed those of the reference building across all three metrics.
H6V2 is a performance solution — not a DtS pathway — meaning it requires a report prepared and certified by a qualified energy assessor. The assessment methodology under H6V2 is governed by the ABCB’s National Construction Code, and practitioner obligations in Victoria are detailed in VBA Practice Note EE-03-2022. For Class 2 SOUs and Class 4 parts of buildings, a parallel verification method, J1V5, applies under Volume One.
The Reference Building Concept Under H6V2
The reference building in VURB Victoria is a notional, hypothetical building that mirrors the proposed design in orientation, floor plan, and volume but is modelled using the minimum DtS provisions of Specification 44 (NCC Volume Two, clauses S44C1 to S44C4). Under H6V2, the same modelling parameters — internal heat gains at 5 W/m² averaged over 24 hours, air infiltration at 0.6 air changes per hour, and climate-zone-specific thermostat settings — are applied to both the proposed and the reference building to ensure a fair thermal performance comparison.
Approved Simulation Software for VURB Victoria Projects
A critical regulatory requirement under VURB NCC 2022 is that the simulation software used for H6V2 must comply with ANSI/ASHRAE Standard 140 (2007 edition). NatHERS-accredited tools — including AccuRate Sustainability and FirstRate5 — are explicitly not permitted under H6V2. This is confirmed both by the VBA Practice Note EE-03-2022 and the NatHERS Administrator. Appropriate tools include DesignBuilder (with EnergyPlus engine), IDA ICE, and TRNSYS — all of which comply with ASHRAE 140 and support hourly climate data modelling required under H6V2.
Victorian Climate Zones Under NCC 2022 — Zones 6, 7, and 8
Victoria spans three NCC climate zones: Climate Zone 6 (mild temperate — metropolitan Melbourne and surrounds), Climate Zone 7 (cool temperate — Central Highlands, Ballarat, Bendigo), and Climate Zone 8 (alpine — Falls Creek, Mount Hotham, alpine regions). Climate zone determines the reference building thermostat settings, fabric R-value requirements, and heating and cooling load thresholds under Specification 44. Zone 8 buildings face the most stringent insulation requirements given the extreme heating demand, while Zone 6 buildings require careful attention to glazing Solar Heat Gain Coefficient (SHGC) to manage cooling loads. Practitioners conducting a VURB Victoria assessment must confirm the applicable zone using the ABCB climate zone map prior to modelling.
4. The VBA Practice Note EE-03-2022: Obligations for Victorian Practitioners
What VBA Practice Note EE-03-2022 Says
The VBA Practice Note EE-03-2022 — Energy Efficiency Requirements for New Residential Buildings — is the primary interpretive guidance document issued by the Victorian Building Authority for energy compliance under NCC 2022 Victoria. It explains the compliance framework for Class 1 and Class 2 residential buildings, covering both DtS and performance solution pathways including VURB Victoria.
VBA Practice Note EE-03-2022 clarifies that the VURB NCC 2022 pathway — under Verification Method H6V2 — constitutes a Performance Solution requiring the proposed building’s annual heating, cooling, and total thermal energy loads to each be equal to or less than those of the DtS-compliant reference building. It also confirms that NatHERS-accredited software cannot be used for this verification, and that practitioners must use H6V2 with software that meets ANSI/ASHRAE Standard 140.
When VBA Practice Note EE-03-2022 Applies
VBA Practice Note EE-03-2022 applies to all new Class 1 residential buildings and Class 2 buildings (including their common areas) in Victoria where building permits are lodged on or after 1 May 2024 under NCC 2022 Victoria. It supersedes the earlier Practice Note EE-03-2019 for all new permit applications. It does not apply to alterations and additions to existing Class 1 buildings — those are governed by Practice Note EE-04-2022.
Practitioner Obligations Under VBA Practice Note EE-03-2022
Under VBA Practice Note EE-03-2022, practitioners conducting or relying on a VURB Victoria assessment must:
- Ensure the simulation software complies with ANSI/ASHRAE Standard 140 and is not NatHERS-accredited
- Model both the proposed and the reference building using the same parameters specified in H6V2(3) and Specification 44
- Submit a detailed energy assessment report to the Relevant Building Surveyor (RBS) as part of the building permit documentation
- Confirm climate zone, orientation, shading, glazing, and services inputs are consistent across both building models
- Demonstrate that all three load benchmarks — heating, cooling, and total thermal energy — are satisfied concurrently.
5. Specification 44 Under NCC 2022 Victoria
What Specification 44 Contains
NCC 2022 introduced Specification 44 to replace the previously qualitative performance requirements with quantified load benchmarks. Specification 44 (clauses S44C1 to S44C4 of NCC Volume Two) provides the formulas and methodology for calculating the maximum allowable annual heating load, cooling load, and total thermal energy load for any given residential building based on its climate zone, floor area, and orientation. Prior to Specification 44, performance solutions were difficult to assess objectively because the NCC did not specify measurable thresholds.
How Specification 44 Defines the Reference Building for VURB Victoria
For VURB NCC 2022 purposes, Specification 44 defines the thermal characteristics of the reference building. The reference building is modelled to the minimum DtS fabric provisions under Parts 3.12.1 to 3.12.4 of the Housing Provisions. Specification 44 sets the heating and cooling load targets that the proposed building must match or undercut. When a VURB Victoria assessment is submitted, the energy assessor uses Specification 44 benchmarks to confirm that the proposed design delivers equivalent or better thermal performance than the notional DtS reference building.
Key Inputs Under Specification 44 for Victorian Projects
The following inputs must be consistently applied under Specification 44 to both the reference and proposed building models in a VURB Victoria assessment:
- Building fabric: Wall, roof, floor, and ceiling insulation R-values per climate zone DtS minimums
- Glazing: U-value and SHGC per climate zone requirements — particularly relevant for Zone 6 (cooling) and Zone 8 (heating)
- Shading: Fixed external shading devices as per DtS provisions; the same shading geometry applied to both models
- Ventilation and air infiltration:6 air changes per hour applied uniformly to both models
- Services: Lighting, hot water, and mechanical heating/cooling systems assessed under the Whole-of-Home framework
Refer to Part H6 of NCC 2022 on the ABCB website for the full operative clauses of Specification 44.
6. VURB Victoria vs NatHERS: When to Choose Each Pathway
When Victorian Practitioners Choose VURB Victoria Over NatHERS
Both VURB Victoria and NatHERS are legitimate compliance pathways under NCC 2022 Victoria, but they serve different situations. Practitioners typically select VURB NCC 2022 when:
- The building uses non-standard construction systems (e.g., rammed earth, polished concrete slab-on-ground, or mass timber) that NatHERS modelling tools cannot accurately represent
- The design’s glazing or shading configuration exceeds NatHERS’s parametric limits
- A volume builder applies the same building template across multiple orientations and sites, making a single VURB model more efficient than repeated NatHERS assessments
- The designer wants to trade off specific fabric elements (e.g., higher U-value glazing) against improved insulation in another area, provided the total load target is still met
Cost, Timeline, and Practical Differences
VURB Victoria assessments generally involve greater upfront modelling effort and cost compared to a standard NatHERS rating, because ASHRAE 140-compliant software requires more detailed inputs and hourly simulation. However, for complex or non-standard designs, VURB NCC 2022 often delivers better outcomes and fewer design compromises. Volume builders applying the same floor plan across many lots frequently find VURB Victoria more cost-effective at scale, as the reference-building approach allows envelope trade-offs without re-running a full NatHERS rating for each site variation.
7. Common VURB Victoria Compliance Questions
Do I Need a Building Permit Amendment if I Change the Design After a VURB Assessment?
Yes. Any material change to the building envelope — including modifications to glazing area, insulation values, orientation, or shading — after a VURB Victoria assessment has been submitted will require the RBS to review whether the amended design continues to comply with H6V2 and Specification 44. Material changes may necessitate a new or updated energy assessment report. Practitioners should consult VBA Practice Note EE-03-2022 and advise their RBS promptly.
Can NatHERS Tools Be Used for VURB Victoria Assessments?
No. NatHERS-accredited software — including AccuRate Sustainability, FirstRate5, and BERS Pro — is explicitly prohibited under H6V2 for VURB Victoria assessments. This is confirmed by both VBA Practice Note EE-03-2022 and the NatHERS Administrator’s guidance. The key reason is that NatHERS tools use different thermostat setpoints and occupancy assumptions to those prescribed under H6V2, which would invalidate the load comparison.
What Documentation Must I Submit to the VBA for a VURB Victoria Assessment?
A VURB Victoria assessment submitted with a building permit application must include: the energy assessment report detailing both the proposed and reference building models; evidence that the simulation software complies with ANSI/ASHRAE Standard 140; climate data files used; summary of Specification 44 load calculations; and certification by a suitably qualified energy assessor. The RBS reviews this documentation to confirm compliance with NCC 2022 Victoria and VBA Practice Note EE-03-2022. Refer to the VBA Practice Note categories page for current guidance documents.
8. Conclusion: Key Takeaways for Victorian Practitioners
For architects, building designers, builders, volume builders, surveyors, and property consultants operating in Victoria, understanding VURB Victoria under NCC 2022 Victoria is now a core compliance competency. Since 1 May 2024, all new residential building permits must satisfy the updated energy efficiency provisions. VURB NCC 2022 — operating through Verification Method H6V2 and underpinned by Specification 44 — provides a performance-based alternative to NatHERS that offers genuine design flexibility when applied correctly.
The VBA Practice Note EE-03-2022 remains the authoritative practitioner guide in Victoria. Key obligations include using ASHRAE 140-compliant software (not NatHERS tools), modelling both the proposed and reference buildings to Specification 44 parameters, and submitting a complete energy assessment report with the building permit application.
At Torple, our accredited energy assessors specialise in VURB Victoria assessments across all Victorian climate zones (6, 7, and 8). Whether you are a volume builder optimising a standard house design across multiple sites, or an architect seeking to achieve compliance for a complex custom home, our team delivers technically robust, VBA-accepted VURB reports. Contact Torple today to discuss your residential energy compliance needs under NCC 2022
FAQs
Victoria adopted the NCC 2022 energy efficiency, condensation management, and livable housing provisions on 1 May 2024. This followed an extension of the original 1 May 2023 national adoption date, confirmed through amendments to the Building Regulations 2018. All new building permit applications for Class 1 and Class 2 residential buildings lodged on or after this date must comply with NCC 2022 Victoria. See the VBA’s NCC 2022 page for confirmation.
VBA Practice Note EE-03-2022 is the Victorian Building Authority’s practitioner guidance document on energy efficiency requirements for new residential buildings under NCC 2022. It explains the DtS and performance solution pathways, including VURB Victoria under H6V2. It confirms that NatHERS software cannot be used for H6V2 and outlines documentation and reporting obligations for energy assessors and RBSs.
Specification 44 (clauses S44C1–S44C4, NCC Volume Two) is the NCC 2022 provision that quantifies maximum allowable heating load, cooling load, and total thermal energy load benchmarks for residential buildings based on climate zone, floor area, and orientation. It replaced previously qualitative performance requirements and is central to both the VURB NCC 2022 pathway (under H6V2) and the performance solution framework for NCC 2022 Victoria. See Part H6 on the ABCB website for operative clauses.
Victoria encompasses three NCC climate zones: Zone 6 (mild temperate — Melbourne metro and surrounds), Zone 7 (cool temperate — Ballarat, Bendigo, Geelong hinterland), and Zone 8 (alpine — Falls Creek, Mount Hotham). Climate zone determines the fabric R-value minimums, glazing requirements, and load benchmarks under Specification 44 and H6V2 for any VURB Victoria assessment. Use the ABCB climate zone map to confirm the correct zone for a project location.
No. NatHERS-accredited software is explicitly prohibited for use under Verification Method H6V2 for VURB Victoria assessments. This is confirmed by both VBA Practice Note EE-03-2022 and the NatHERS Administrator. Practitioners must use ANSI/ASHRAE Standard 140-compliant simulation tools such as DesignBuilder, IDA ICE, or TRNSYS for VURB NCC 2022 assessments.
VURB Victoria does not replace NatHERS. Both pathways coexist under NCC 2022 Victoria. NatHERS remains the standard Deemed-to-Satisfy tool for achieving the 7-star energy rating under H6D2. VURB NCC 2022 under H6V2 is a performance solution pathway offering design flexibility where NatHERS is impractical or suboptimal. Practitioners choose between them based on the design complexity, construction system, and project requirements, with reference to VBA Practice Note EE-03-2022.
A complete VURB Victoria submission to the RBS for a building permit must include: (1) an energy assessment report covering both the proposed building and the Specification 44-compliant reference building models; (2) evidence of the simulation software’s compliance with ANSI/ASHRAE Standard 140; (3) the hourly climate data file used; (4) the H6V2 load comparison demonstrating all three load limits are met; and (5) assessor credentials and certification. VBA Practice Note EE-03-2022 and the VBA’s NCC 2022 resources page provide further guidance.